CHP2000
Cat G3516H Combined Heat and Power (CHP) Solution
The CHP2000 is an enclosure standardized for natural gas-fueled Cat® G3516H engines rated 2.0 MW, with generator rated for 4160V for combined heat and power (CHP) applications. In CHP applications, Cat gas generator sets simultaneously provide electricity for electrical loads and heat energy for a facility’s thermal requirements. Caterpillar will offer customers complete CHP solutions eliminating the need to outsource additional engineering or project management.
Cat® G3516H Humidity Fuel Tolerant Gas Engine
- Robust high speed block design provides prolonged life and lower owning operationg costs
- Designed for maximum performance on low pressure pipeline natural gas
- Simple open chamber combustion system for reliability and fuel flexibility
- Leading edge technology in ignition system and air/fuel ratio control for lower emission and engine efficiency
- One electronic control module handles all engine functions: ignition, governing, air/fuel ratio control and engine protection
CHP Ready
Extensive range of rental ready features to meet job requirements and applications.
Single-Source Supplier
Generator set manufactured in ISO 9001:2000 compliant facility.Package factory designed and production tested.
EMCP 4.3 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cat Generator
Cat SR5 generator designed to match the performance and output characteristics of the Cat Gas engine.Class H insulation operating at Class F temperature rise for extended life.System 4 insulation protection and anti-condensation space heaters.Integrated Automatic Voltage Regulation (Cat IVR) provides enhanced system monitoring.
Fuel/Emissions Strategy
Meets most worldwide emissions requirements down to 500 mg/Nm3 NOx level without after treatment.Optional: Oxidation catalyst available
Sound Attenuated Container
Meets 75 dB(A) at 7 meters. Weather Proof enclosure, NSPS factory compliant, UL2200 compliant, and CSA/TSSA. Service and Personnel doors. Separate electrical control room. Internal and External emergency stop buttons at convenient locations.
Proven System
- Field proven in a wide range of applications worldwide
- Fully prototype tested
- Certified torsional vibration analysis available
Reduced Environmental Impact
110% spill containment of onboard engine fluids.Positive crankcase fumes ventilation.
Full Range of Attachments
- Wide range of bolt-on system expansion attachments
- Factory designed and tested
- Flexible packaging options for easy and cost effective installation
Worldwide Product Support
Cat® dealers provide extensive post sale support including maintenance and repair agreements. Supported 100% by the Cat dealer with warranty on parts and labor.
Cooling System
Provides 40⁰C (104⁰F) ambient capability with 500 mg/Nm3 NOx (1g/hp-hr) at 100% continuous rating before derate @ 500m. Variable frequency drive fan controls improve partial load fuel consumption. Energy efficient electric drive fan.
Virtual Tours
Documents & Brochures
Standard Equipment
Engine
- G3520H, V20, 4-stroke-cycle, gas engine.
Operates on 31.5 to 47.2 MJ/NM3 dry pipeline natural gas.
Turbocharged Separate Circuit Aftercooled.
Control Panel
- On Package EMCP 4.3 Control Panel System
Offers engine and generator monitoringand protection, voltage regulation with Cat IVRimproves transient response performance.
Controls provide auto paralleling AGC-4 controller, load sharing, VFDcontrol, and primary generator protection for greaterversatility, package utilization and monitoring.
Air Inlet
- Package Mounted Air Cleaner with service indicator
Cooling
- ANSI/DN customer flange connections for JW inlet and outlet
- Engine driven water pumps for jacket water and aftercooler
- Jacket water and SCAC thermostats
- Standard cooling provides 40⁰C (104⁰F) ambient capability with 500mg/Nm3 NOx at 100% Continuous rating before derate, @ 500m
Containerized Module
- NSPS Factory Compilant, UL2200 Compilant and CSA / TSSA
Sound attenuated 75 dB(A) @ 7 m (23 ft)
Sound attenuated air intake louvers and lockable personnel doors with panic release
LH and RH engine service doors integrated intocontainer side walls
3” ANSI flange customer fuel connection
Generator Controls And Protection
- Integrated crankcase ventilation system (CCV)and gas fuel train NFPA37 & CSAB149.3
with external fuel connections package utilization and monitoring.
Modes of Operation
- Provides for single unit stand-alone operation,island mode paralleling and load sharing withother power modules, and single unit-to-utilitymode paralleling for base load control
Lube Oil Make-Up System
- Integrated enclousre holding tanks: Oil makeup tank (50 gallon), Waste oil tank
(300 gal / 2 oil changes), Fresh oil tank (500 gal / 2 oil changes + makeup) and oil level regulator.
Low level annunciation
Exhaust
- Externally mounted exhaust system (muffler and heat exchanger)
- Dry exhaust manifolds, insulated and shielded
- Individual exhaust port and turbocharger outlet wired to Integrated Tmeperature Sensing Module (ITSM) with GECM providing alarms and shutdowns
- Center section cooled turbocharger with Cat flanged outlet
General
- Fire detection system
Circuit Breaker
- LSI Long-Time, Short-Time, Instantaneous Annunciator
- 5000A 3-Pole IEC Rated Circuit Breakers
- Rear-mounted
Fuel System
- Electronic fuel metering valve
- Throttle plate, 24V DC actuator, controlled by GECM
Fuel system
- Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve
Ignition System
- Electronic Ignition System (controlled by ADEM A4)
- Individual Cylinder Detonation Sensitive Timing (DST)
Generator
- Double bearing SR5 1866 frame, brushless, form wound, 12-lead design, permanent magnet excited, three-phase, with Cat IVR, Class H insulation operating at Class F temperature.
Stator and Bearing temperature monitoring and anti-condensation space heaters. - SR4B
- Caterpillar's Digital Voltage Regulator (CDVR) with 3-phase sensing and KVAR/PF control
- Paint- Caterpillar Yellow except rails gloss black
- Busbar connections
- Crankshaft Vibration Damper and Guard
- Parts book
- Reactive droop
- SR5
- Anti-condensation space heater
- RH Service
- Operation and maintenance manuals
- Winding temperature detectors
Govrerning System
- ADEM A4 4-20mA (0-5VV) Speed Input
Additional information
مواصفات مجموعة المولدات - الحد الأقصى للتقديرات المتواصلة | 1982 كيلووات كهربائي عند معامل طاقة 1.0 |
---|---|
مواصفات مجموعة المولدات - نوع الوقود | الغاز الطبيعي |
مواصفات مجموعة المولدات - أقصى كفاءة كهربائية | 42.90% |
مواصفات مجموعة المولدات - التردد | 60 هرتز |
مواصفات مجموعة المولدات - دورة في الدقيقة | 1500 |
مواصفات المحرك - موديل المحرك | G3516H |
مواصفات المحرك - الإزاحة | 78 l ( 4765 بوصة³ ) |
مواصفات المحرك - السحب | TA |
مواصفات المحرك - التجويف | 170 مم ( 6.7 بوصة ) |
مواصفات المحرك - الشوط | 215 مم ( 8.5 بوصة ) |
مواصفات المحرك - نظام الوقود | صمام تحكم إلكتروني في الوقود |
مواصفات المحرك - نوع المنظم | ADEM™ A4 |
أبعاد مجموعة المولدات - الطول | 18200 مم ( 716 بوصة ) |
أبعاد مجموعة المولدات - العرض | 3940 مم ( 155 بوصة ) |
أبعاد مجموعة المولدات - الارتفاع | 11850 مم ( 467 بوصة ) |
أبعاد مجموعة المولدات - الوزن الجاف - مجموعة المولد | 18,315 كجم ( 40,384 رطل ) |
أبعاد مجموعة المولدات - الوزن | 75,500 كجم ( 166,600 رطل ) |
مواصفات المحرك - نسبة الانضغاط | 11.1 |
Offering Type |