3516E (50 Hz)

3516E Generator Set

The 3516E diesel generator sets have been developed to meet your standby, mission critical and prime applications and match your power standards. Producing reliable power (3000 – 3500 kVA at 50 Hz), each generator set has been designed to meet ISO 8528-5 transient response requirements and to accept 100 % rated load in one step. The generator is certified Tier 2 Equivalent, US EPA Stationary Emergency / Low NOx (1/2 TA Luft).

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

SR5 Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

Cat Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 50�C (122�F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

  • EU Declaration of Conformity
  • EU Declaration of Incorporation
  • Eurasian Conformity (EAC)

One Safe Source

  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Worldwide Product Support

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Standard Equipment

Air Inlet System
  • Air cleaner; single element canister type
Control System
  • Text alarm/event descriptions
  • Emergency stop pushbutton
  • IVR includes reactive droop capability
  • KVAR / PF modes
  • EMCP 4.2B
  • 3 Phase voltage sensing
  • Generator mounted - rear facing
  • Generator set packages include:
  • 24 Volt DC operation
  • Caterpillar's voltage regulator
  • RFI suppression
  • Environmental sealed front face
  • Limiter and exciter diode monitor
  • Min / max exciter
  • Controls:
  • Speed adjust
  • Alarm acknowledge
  • Auto/start/stop control
  • Engine cycle crank
  • Engine cool
  • Customizable screens
  • PLC functionality
  • Lamp test
  • Load histogram feature
  • Accessory module data link
  • Reverse power (kW) (32)
  • 6 Customer programmable digital inputs
  • 3 Phase
  • +/- 2% accuracy
  • High coolant temperature
  • 0 True RMS AC metering
  • Programmable protective relaying functions:
  • Reverse reactive power (kVAr) (32RV)
  • Communications:
  • Generator phase sequence
  • Over/under voltage (27/59)
  • Overcurrent (50/51)
  • RPM
  • Number of I/O varies on options selected
  • Overspeed
  • Serial annunciator module data link
  • Low coolant temperature
  • 4 Programmable relay outputs (Form A)
  • 1 Programmable relay outputs (Form C)
  • 3 Analog inputs
  • Over/under frequency (81 o/u)
  • Digital indication for:
  • Low coolant level
  • Failure to start (overcrank)
  • Cat connect
  • 1 Programmable digital outputs
  • DC volts
  • Operating hours
  • Coolant temperature
  • Oil pressure (psi, kPa or bar)
  • Amps (per phase & average)
  • Power factor (per phase & average)
  • Frequency (Hz)
  • Volts (L-L & L-N)
  • kW (per phase, average & percent)
  • kVA (per phase, average & percent)
  • kVAr (per phase, average & percent)
  • Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level -
  • Low oil pressure
  • kW-hr (total)
  • kVAr-hr (total)
Cooling System
  • ATAAC - 3516E package radiators shipped installed
  • Certified standard PGS provided
Exhaust System
  • Flanged faced outlet(s)
  • Dry exhaust manifold
Fuel System
  • Secondary fuel filters
  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose
General
  • Right hand servicing
  • Caterpillar yellow with high gloss black rails and radiator
  • SAE standard rotation
  • Flywheel and flywheel housing - SAE No. 00
Generator and Attachments
  • NEMA standard hole pattern
  • Medium voltage:
  • Anti-condensation space heater
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient
    (125C prime/150C standby)
  • Winding temperature detectors
  • High voltage:
  • Busbar connections, right side extension box, bottom cable entry
  • Form wound
  • Low voltage: Random wound - Internal excitation (IE) - Winding temperature detectors - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby) - Busbar connections, top center mounted, top cable entry - NEMA standard hole pattern
  • 6 Lead
  • Permanent magnet excitation (PMG)
  • 3 Phase brushless, Salient pole
  • Class H insulation, Class F temperature rise at 40C ambient
    (105C prime / 130C standby)
Governing System
  • ADEM A5
Literature
  • Parts book
  • Operation & Maintenance Manual
Lubrication System
  • Integral lube oil cool
  • Oil filter, filler and dipstick
  • Oil drain lines and valve
  • Gear type lube oil pump
  • Lubricating oil
  • Fumes disposal
Mounting System
  • Rails - Engine/generator/radiator mounting
  • Anti-vibration mounts (shipped loose)
  • Rubber anti-vibration mounts - shipped loose
Starting System
  • 24 Volt electric starting motor
  • Battery disconnect switch
  • Battery and battery rack w/cables
  • 45 Amp Charging alternator

Additional information

Offering Type

Generator Set Specifications - Maximum Rating

3500 kVA

Generator Set Specifications - Minimum Rating

3000 kVA

Generator Set Specifications - Emissions/Fuel Strategy

Tier 2 Equivalent – 1800 rpm

Generator Set Specifications - Voltage

380 to 11000 volts

Generator Set Specifications - Frequency

50 Hz

Generator Set Specifications - Speed

1800 rpm

Generator Set Specifications - Duty Cycle

Standby, Mission Critical

Engine Specifications - Engine Model

3516E, V-16, 4-Stroke Water-Cooled Diesel

Engine Specifications - Bore

170 mm ( 6.69 in )

Engine Specifications - Stroke

215 mm ( 8.46 in )

Engine Specifications - Displacement

78.1 l ( 4765 in³ )

Engine Specifications - Compression Ratio

14.7:1

Engine Specifications - Aspiration

ATAAC

Engine Specifications - Fuel System

Electronic Unit Injection

Engine Specifications - Governor Type

Adem™5

Generator Set Dimensions - Length - Minimum

8513 mm ( 335.1 in )

Generator Set Dimensions - Length - Maximum

8513 mm ( 335.1 in )

Generator Set Dimensions - Width - Minimum

2640 mm ( 104 in )

Generator Set Dimensions - Width - Maximum

2460 mm ( 104 in )

Generator Set Dimensions - Height - Minimum

3342 mm ( 132.6 in )

Generator Set Dimensions - Height - Maximum

3342 mm ( 131.6 in )

Generator Set Dimensions - Dry Weight - Genset (minimum)

21,600 kg ( 47,620 lb )

Generator Set Dimensions - Dry Weight - Genset (maximum)

23,000 kg ( 50,706 lb )